The CIRAS-2 is a "true differential" system. It features four
independent, non-dispersive infrared gas analyzers for accurate,
simultaneous measurement of both CO2 and H2O,
eliminating the problems associated with "gas switching" systems.
Three input channels are available for % R.H., temperature and PAR sensors plus a full range of cuvettes
and chambers for leaf gas exchange, whole plant gas exchange, soil respiration and
chlorophyll fluorescence measurement. |

Ciras-2
Portable Photosynthesis System
|
|
ACCUPAR LP-80 offers improved flexibility for measuring Photosynthetically Active Radiation (PAR) and Leaf Area Index (LAI). ACCUPAR
LP-80 utilizes an 80cm probe containing 80
photo diode sensors, which can easily detects gradual light changes
at all levels of your plant canopy. It also inverts PAR to interrogate sensors individually or average PAR readings throughout the canopy. |

ACCUPAR
LP-80
|
|
The EMS-7 is a portable system for the determination of PAR above
and within plant canopies. As such, it is extremely useful in
plant physiological and ecological studies. |

EMS-7
Plant Canopy Transmission Meter
|
|
- SpectroSense2 is 4-Channel meter for light sensors
- SpectroSense2+ is an 8-channel logger & meter
- Designed for single channel, 2-channel, or 4-channel sensor types
- Can also be used with light sensors from most other manufacturers
- SpectroSense2 displays readings from 4 sensors or channels simultaneously and SpectroSense2+displays and logs from 8 sensors or channels
- Displays sensor ratios for NDVI calculations
- Hold & store functions
- Ideal for ground truth measurements
|

SpectroSense2 with NDVI Application |
|
These sensors, traditionally used in plant growth studies, count the number of quanta
falling between 400 and 700 nm.
The PAR Quantum is the sensor with the ideal 100% quantum efficiency curve and is
traditionally used in plant growth studies. The spectral response has been well researched
and documented and is widely accepted as 'the standard'.
|

PAR Quantum (SKP 215) & PAR 'Special' (SKP 210)
|
|
A 2-channel sensor with narrow band filters centred at 660nm and 730nm. A very popular
filter combination important for plant phytochrome studies, and controlling plant
responses in mixed lighting conditions.
|

Red/Far-Red Sensor (SKR 110)
|
|
The FieldScout CM 1000 NDVI Meter uses ¡°point-and-shoot¡± technology to instantly
measure reflected light in the red (660nm) and near infrared (840nm) spectral
bands. Meter uses red and near infrared reflectances to calculate NDVI. At
12in(30cm), it integrates a 1.5in(4cm) diameter area on a plant leaf or, at
4ft(1.2m), a 4.5in(11cm) diameter spot on a plant. Laser guides outline the
edges of the measured sample area. An ambient light sensor automatically
corrects measurements for varying light conditions. The handheld meter
calculates and displays a running average for multiple readings. |

FieldScout CM 1000 NDVI Meter
|
|
The SPAD 502 Plus Chlorophyll Meter instantly measures chlorophyll content or ¡°greenness¡± of your plants to reduce the risk of yield-limiting deficiencies or costly overfertilizing. The SPAD 502 Plus quantifies subtle changes or trends in plant health long before they¡¯re visible to the human eye. Non-invasive measurement; simply clamp the meter over leafy tissue, and receive an indexed chlorophyll content reading (0-99.9) in less than 2 seconds. Assess nitrogen needs by comparing in-field SPAD readings to university guidelines or to adequately fertilized reference strips. Research shows a strong correlation between SPAD measurements and leaf N content.
New features in the SPAD 502 Plus include:
|

SPAD 502 Plus & 502DL Plus
|