Wall-mounted Doppler Ultrasonic Flow Meter
Enquiry

 Specifications: Transmitter 

Measurement principle

Doppler ultrasonic

Resolution

0.25mm/s

Repeatability

0.2% of reading

Accuracy

0.5% -- 2.0% F.S.

Response time

2-60s for optional

Flow Velocity Range

0.05- 12 m/s

Liquid Types Supported

Liquids containing 100ppm of reflectors and at least 20% of the reflectors are larger than 100 micron.

Power Supply

AC: 85-265V   DC: 24V/500mA

Enclosure type

Wall-mounted

Degree of protection

IP66 according to EN60529

Operating temperature

 -20 to +60

Housing material

Fiberglass

Measurement Channels

1

Display

2 line × 8 characters LCD, 8-digit rate or 8-digit total (resettable)

Units

User Configured (English and Metric)

Rate

Rate and Velocity Display

Totalized

gallons, ft³, barrels, lbs, liters, m³,kg

Communication

4-20mA,relays for Totalizer and alarm output

keypad

6pcs buttons

Size

244(h)*196(w)*144(d)mm

Weight

2.4kg

 

 Specifications: Transducer

Transducers Type

Clamp-on

Degree of protection

IP65. IP67 or IP68 according to EN60529

Suited Liquid Temperature

Std. Temp.: -35~85 for short periods up to 120

High Temp.: -35~200 for short periods up to 250

Pipe diameter range

25-4000 mm

Transducer Size

60(h)*34(w)*32(d)mm

Material of transducer

Stainless steel

Cable Length

Std: 10m