Soil Chemical Content Analysis

   
««First   «Prev   [1]  [2]  [3]  [4]  Next»  Last»»
Nitrachek Reflectometer
Eijkelkamp 18.40 Nitrachek Reflectometer

Product Features
 
  • A pocket size digital measuring instrument.
  • Eijkelkamp 18.40 Nitrachek Reflectometer for a simple and quick determination in the field of the nitrate content in water or in a watery extract of soil or crop.
  • Based on read-out of nitrate test strips. After a test strip is held in the solution it is placed in the optical read-out apparatus.
  • Up to 20 measuring sets with date/ time indication.
  • Measuring range of 5 - 500 ppm (mg/l) nitrate.
  • Accuracy of 1 mg/l.
  • The instrument is supplied including case, test strips, calibration solution and accessories.






pH Field Analysis Set
Eijkelkamp 18.44 pH Field Analysis Set

Product Features
 
  • Eijkelkamp 18.44 pH Field Analysis Set for the direct determination of the pH of soils (and liquids) a special electrode is used.
  • Measurement of pH is based on semi conductor technology.
  • The special, sturdy electrode, contains an Ion Sensitive Field Effect Transistor (ISFET) sensor, a silver/silverchloride potassium-chloride reference system and a thermistor to allow for automatic temperature compensation.
  • The electrode has a measuring range of 0-14 pH with an accuracy of 0.03 pH.
  • Measurement depth is 80 mm.
  • The electrode is used in combination with a multimeter.
  • The complete set includes the multimeter with electrode, a small pre-drill auger land with thumb spatula and calibration liquids






EC-Probe For Salinity Measurements
Eijkelkamp 14.01 EC-Probe For Salinity Measurements

Product Features
 
  • To determine the salinity of a soil electrically.
  • In combination with an earth resistivity meter, the resistivity of the soil is measured, and this reading is subsequently converted into electrical conductivity. This conductivity depends on the structure and texture of the soil, the moisture content and the salinity of the ground water.
  • The method is less accurate than a soil sample analysis in a laboratory set-up, but for an estimate of the salinity this method is highly satisfactory.
  • Eijkelkamp 14.01 EC-Probe For Salinity Measurements can be used to perform many comparative measurements in a certain area in a short period of time.
  • Consist of a stainless steel bar, provided with a detachable handle. The bar is provided with a 10 cm graduation. Inside the actual probe, at the bottom of the bar, there are four electrodes, separated by a sealing ring and a insulation ring.
  • Proper contact (= low contact resistance) with the surrounding soil is necessary to facilitate measurements with the EC-probe.
  • To establish proper contact, first the gouge auger is used to make a pilot hole to the desired depth. The drilled out soil can be used as a reference sample to determine the calibration curve.
  • In every EC-measurement, the temperature of the soil stratum that is to be read must also be measured. For this purpose, the tip of the probe is provided with a temperature sensor.
  • Having measured the earth resistivity, the temperature correction factor is determined. The temperature coefficient can be read before the electrical conductivity is calculated.
  • The standard set inlcudes: the EC-probe, an earthresistivity meter, the single gouge auger, a spatula and a strong transport bag.






Soil Temperature Sensor
Seba Soil Temperature Sensor

Product Features
 
  • Seba Soil Temperature Sensor  for soil temperature in different depths according specification.
  • Accuracy: 0.3 °C. 






IR Temp Meter
Spectrum IR Temp Meter

Product Features
 
  • Infrared technology makes difficult measurements fast, easy and affordable
  • An excellent tool for measuring the temperature of turf and plant canopies
  • Spectrum IR Temp Meter use selectable laser pointer to identify target spot
  • Backlit LCD display
  • Includes 9V battery, wrist strap and case 






IR Temp Meter / External Temp Meter
Spectrum IR Temp Meter / External Temp Meter

Product Features
 
  • Spectrum IR Temp Meter / External Temp Meter one lightweight handheld device easily measures both leaf and soil temperatures
  • Backlit LCD display
  • Includes 9V battery, wrist strap and case 






soil thermometer
Spectrum Soil Thermometers

Product Features
 
  • Pocket-sized meters built of tough, corrosive-resistant stainless steel
  • Spectrum Soil Thermometers Digital meter (model 6300) - Dual-mode LCD updates in 1- or 15-second intervals - Adjustable nut provides quick calibration - Measures from 0° to 160°F (-17° to 71°C) - Accuracy ± 2°
  • Analog meter (model 6305) - Easy-to-read dial - Measures from 25° to 125°F - Accuracy ± 1°
  • Digital meter, Long-Stem (model 6310) - Extended 8 in (20 cm) stem - Measures from -58° to 302°F (-50° to 150°C) - Accuracy ± 1.8°






External (Soil) Temperature Sensors
Specturm External (Soil) Temperature Sensors

Product Features
 
  • Specturm External (Soil) Temperature Sensors measure soil, air, or water temperature with a resistance-based sensor.






FieldScout EC 110 Meter
Spectrum FieldScout EC 110 Meter

Product Features
 
  • Spectrum FieldScout EC 110 Meter combines Spectrum’s patented direct-insert EC probe with a built-in data logger
  • Accuracy of ± 2%
  • Measurement ranges: – 0.00 to 199.9 µS/cm (resolution 1 µS/cm) – 0.0 to 19.9 mS/cm (resolution 0.01 mS/cm)
  • Geo-reference your data by connecting to any GPS receiver with serial output option
  • Equipped with internal data logger and RS-232 port
  • Records 4,096 measurements (1,488 with added GPS/DGPS option)
  • Configure and download meter with FieldScout software (included)
  • Compatible with SpecMaps online web-mapping application
  • Includes hard carrying case, Conductivity Cell (Item 2220CC), software, four AAA batteries, PC interface cable and EC calibration standard






FieldScout Direct Soil EC Meter
Spectrum FieldScout Direct Soil EC Meter

Product Features
 
  • Spectrum FieldScout Direct Soil EC Meter patented paired sensor tip provides maximum soil-sensor contact and higher accuracy - U.S. PATENT NO. 7,183,779
  • Sample directly in plug trays, pots, containers or solutions
  • 0 to 19.9 mS/cm (Accuracy ± 2%, resolution 0.01 mS/cm)
  • Automatic temperature compensation
  • Includes battery and EC calibration standard