Electric Anchor Load Cells
The Electric Anchor Load Cells consists of a ring-shaped stainless steel body which incorporates from 8 to 16 electrical resistance strain gauges in full bridge configuration. This configuration allows low sensitivity to eccentric load. Typical applications include performance testing of anchor systems in tunneling or deep excavations. The cell design minimizes the sensitivity to the eccentric load. Anchor load cells are available in a variety of ranges and diameters. A very stiff distribution plate is supplied, in order to ensure that the load is applied equally over the anular loading surface of the cell.
Model | Standard Model | Extended Temperature Model |
---|---|---|
Full scale capacity kN | from 300 to 2500 kN | from 300 to 2500 kN |
Overload | 1.5 X Full scale | 1.5 X Full scale |
Repeatability | < ±0.02% FS | < ±0.02% FS |
Stability @1 year | ±0.05% FS | ±0.05% FS |
Accuracy Pol. MPE | < ±0.5% FS | < ±0.5% FS |
Thermal zero shift | < 0.005% FS / °C | < 0.005% FS / °C |
Signal output | 1.5 mV/V at FS 2.0 mV/V only for 2500 kN FS |
1.5 mV/V at FS 2.0 mV/V only for 2500 kN FS |
Power supply | from 5V DC to 10V DC | from 5V DC to 10V DC |
Bridge resistance |
700 Ω FS from 300 to 750 kN (8 strain gauges) |
700 Ω FS from 300 to 750 kN (8 strain gauges) |
Operating temperature range | -20°C +70°C | -30°C +70°C |
Compensated temperature range | -10°C +40°C | -30°C +70°C |
Temperature effect on zero | < ±0.002% FS / °C | < ±0.002% FS / °C |
Temperature effect at FS | < ±0.002% FS / °C | < ±0.002% FS / °C |
Body material | stainless steel 17-4 PH | stainless steel 17-4 PH |
Protection | IP68 up to 100 kPa | IP68 up to 100 kPa |