Hydraulic Anchor Load Cells

The hydraulic anchor load cells are used to monitor loads in tiebacks, rock bolts and cables. They consist of two ring-shaped stainless steel plates welded together around their circumference. The anular space between the plates is filled under vacuum by deaired oil. The load is directly measured by a Bourdon manometer connected to the cell body. The manometer is calibrated in laboratory to allow direct readings in KN. Electrical models equipped with pressure transducer is also available for remote readings. A very stiff distribution plate is supplied, in order to ensure that the load is applied equally over the loading surface of the cell.
Model L2M0 MODEL L2E0 MODEL
Model Description Hydraulic load cell equipped with Bourdon gauge manometer Hydraulic load cell equipped with electrical pressure transducer
Full scale capacity from 300 to 1500 KN from 500 to 1500 KN
Overload 120% with less than 2% FS zero shift 120% with less than 2% FS zero shift
Resolution ≤ 0.5% FS ≤ 0.025% FS
Signal output   4-20 mA
Accuracy manometer class ±1.5 % FS ±1% FS
Material AISI 304 stainless steel AISI 304 stainless steel
Temperature drift 0.25 KN/°C 0.05 F.S./°C
Distribution plate OD equal to the cell loading area equal to the cell loading area
Compensated temperature range -35°C + 60°C -35°C + 60°C