Pneumatic Gauge PS-Sensor
High-precision:
Equipped with two pressure sensors and an automatic pressure range detection, the PS sensor also meets the highest demands on measuring accuracy. In addition, the typical, age-related drift of pressure sensors is compensated by an automatic, processor-controlled 0-point calibration before each measurement. This means that even after many years of operation, the bubbler system is just as precise as on the first day.
Maintenance-free:
Due to the measuring principle, the pressure measuring cell does not come into direct contact with the measuring medium water. Regular, often maintenance-intensive cleaning of the measuring cell due to deposits (e.g. lime, bio-film) is not necessary. The automatic blow-through device in the PS sensor ensures that the pressure transmission line is flushed regularly, thus preventing the bead nozzle from silting up.
Safe:
After the PS sensor can be safely housed in the water gauge house or switch cabinet, mechanical damage, e.g. from vandalism, flotsam, etc., can be ruled out. Cost-intensive lightning protection measures can also be dispensed with on the sensor side, as the air introduced into the water by the PS sensor is non-conductive.
Compatible:
The PS sensor has all common analog and digital outputs and can be connected to all SEBA data collectors, to data collectors of other manufacturers (e.g. via SDI-12) and to process control systems (e.g. via Modbus, 4-20mA).
Everything in it, everything on it:
Extremely compact and equipped with an integrated compressor and air reservoir, a display with function keys, an automatic blow-through device and further features, the PS sensor leaves nothing to be desired.
Water Level
Sensor | Relative pressure probe, microprocessor compensated (32Bit) |
---|---|
Measurement Principle | Bubbler principle (pneumatic) |
Measuring Range |
0 - 10 / 0 - 4 m 0 - 17 / 0 - 4 m 0 - 20 / 0 - 4 m 0 - 30 / 0 - 6 m 0 - 35 / 0 - 6 m 0 - 40 / 0 - 6 m |
Measuring Accuracy | +/- 0,05 % FS = 1 cm bei 0-20 m measuring range |
Measuring Interval | ≥ 1 min |
Housing
Material | Synthetic (Polycarbonate) |
---|---|
Dimensions | 430 x 330 x 190 mm (LxBxH) |
Display | 3 lines, 16 characters (optional: backlight) |
Keyboard | 3 function keys |
Protection Class | IP65 |
Fastening | Wall mounting |
Dosing Valve | Stepless (for adjustment and monitoring of the air volume) |
Compressor | 7bar (101,5 psi) |
Air Storage | 0.75 litre, stainless steel |
Automatic Flushing Mechanism | Adjustable (1/6/12/24 h) to prevent sludge formation / Contamination of the beading out opening |
Communication Interface | RS232, USB, Bluetooth |
Outputs
Digital | RS485: SHWP, SDI-12, MODBUS |
---|---|
Analog | 4...20mA, 0-1V, 0-5V |
Others
Power Supply | 10...15 VDC |
---|---|
Operating Temperature | -35° C ... +65° C |
Cable | 2 m signal cable included |