Pressure probe DS(T) 22
Uncomplicated:
The DS (T) 22 can be connected to all standard data loggers and controllers (PLCs). Either analog (4-20 mA with extended ESD protection according to IEC 61000-4 part 5, 0-1 V) or digital output signals (SHWP, MODBUS, SDI-12) can be ordered.
Saltwater-resistant:
For special applications, e.g. in coastal areas, brackish water or landfills, the DS (T) 22 is also available in high-grade stainless steel 1.4539 form.
Last but not least:
In addition to the measurement of the water level, upon request, water temperature can also be recorded with a high degree of accuracy: 0.1° C.
Water Level
Sensor | Relative pressure sensor |
---|---|
Measurement Principle | Capacitive with ceramic measuring cell |
Measuring Range |
0-2/0-4/0-5/0-10/0-20/0-30/0-40/0-50/0-70/0-100/0-200/0-250/0-300m water column |
Measuring Accuracy |
Digital: ± 0.05% FS Analog: ± 0.1% FS |
Long Term Stability | ±0.1 %/year |
Water Temperature (Optional)
Sensor | PT1000 sensor |
---|---|
Measurement Principle | Resistiv |
Measuring Range |
Digital: -5 °C - +50 °C Analog: -5°C - +60°C |
Measuring Accuracy | 0.1 °C |
Housing
Material | V4A standard 1.4404 stainless steel ,or high grade 1.4539 stainless steel (optional) |
---|---|
Dimensions | Ø22mm x 182mm |
Protection Class |
Probe: IP68 |
Outputs
Digital | RS485: SHWP, Modbus, SDI-12 |
---|---|
Analogue | 0-1V, 4-20mA with extended ESD protection according to IEC 61000-4 part 5 |
Others
Power Supply | 7-30VDC |
---|---|
Connection | Either with plug or open cable ends |
Operating Temperature | -5 °C - +60 °C (non-freezing) |
Cable | Reinforced measuring cable with a pressure compensation line |